MEA - CHARACTERISTICS
Circuitry |
| Rating |
- 6A at 125 or 250V AC
- 0.4A at 125V DC
|
| Operating speed |
|
| Operating frequency |
- Mechanically: 120 operations/min.
- Electrically: 30 operations/min.
|
| Contact resistance |
|
| Insulation resistance |
|
| Dielectric strength |
- 1,000 VAC, 50/60 Hz for 1 minute between non-continuous terminals
- 1,500 VAC, 50/60 Hz for 1 minute between each terminal and non-current carrying metal part and between each terminal and ground
|
| Vibration |
- Malfunction durability: 10 to 55Hz 1.5mm double amplitude
|
| Shock |
- Mechanical durability: Approx 1,000m/sec (approx 100G's)
- Malfunction durability: Approx. 300m/sec (approx 30G's)
|
| Ambient operating temperature
|
- General purpose type: -15º to +70º C
|
| Humidity |
|
| Service life |
- Mechanically: 10,000,000 operations min
- Electrically: 500,000 operations min.
|
| Degree of protection |
|
FEATURES |
- Total plastic enclosure, light weight switches
- Wide choice of heads and actuators
- Captive cover screws
- Mode of operation is filed adjustable
|
- Dust proof, Oil-Tight, Water-Resistant
- 2 circuits: 1 N.O. 1 N.C. contacts design
- Temperature range +5º F to +160º F
- Temperature range -15º C to 70º C
|
Field Adjustable
Rotary motion roller lever and rod actuators are adjustable
through 360°. They may be set for operation clockwise, counter-clockwise,
or in both directions. Operating heads may be positioned in
any of four 90° and four 45° positions.

|
Easy Wiring
-
Loosen cover screws and remove cover
-
Remove rubber strain relief from switch cover
-
Slip strain relief cover cable
-
Fasten terminal screws tightly after inserting cables or terminals
-
After wiring, insert strain relief into the groove of the switch cover
-
Fasten 3 cover screws evenly. Do not over tighten
-
Recommended Cable #18/2 SJT Flexible
|

|