| Rating |
- 10A at 250V AC
- 0.5A at 125V DC
|
| Operating speed |
- 0.01mm to 50cm/sec (at pin plunger)
|
| Operating frequency |
|
| Contact resistance |
|
| Insulation resistance |
|
| Dielectric strength |
- 1,000 VAC, 50/60 Hz for 1 minute between non-continuous terminals
- 2,000 VAC, 50/60 Hz for 1 minute between current-carrying and non-current carrying parts and between each terminal and ground
|
| Vibration |
- Malfunction durability: 10 to 55Hz
- 1.5mm double amplitude
|
| Shock |
- Mechanical durability: Approx 1,000m/sec (approx 100G's)
- Malfunction durability: Approx. 300m/sec (approx 30G's)
|
| Ambient operating temperature |
- Operating: -10º to +80 º C
|
| Humidity |
- 90% RH max, (at +20º C to 35º C)
|
| Service life |
- Mechanically: 10,000,000 operations min. (at rated OT value)
- Electrically: 500,000 operations min.
|
| Degree of protection |
|