MV - CHARACTERISTICS |
| Rating |
- 5A at 125 or 250V AC
- 0.5A at 125 or 250V DC
|
| Operating speed |
|
| Operating frequency |
- Mechanically: 600 operations/min
- Electrically: 60 operations/min.
|
| Contact resistance |
|
| Insulation resistance |
|
| Dielectric strength |
- 1,000 VAC, 50/60 Hz for 1 minute between non-continuous terminals
- 2,000 VAC, 50/60 Hz for 1 minute between current-carry part and ground
|
| Vibration |
- Malfunction durability: 10 to 55Hz 1.5mm double amplitude
|
| Shock |
- Mechanical durability: Approx 1,000m/sec (approx 100G's)
- Malfunction durability: Approx. 300m/sec (approx 30G's)
|
| Ambient operating temperature |
- General purpose type: -25º to +80º C
- High purpose type: 25º to +120º C
|
| Humidity |
- General purpose type: 85% RH max
- Sealed type: 95% RH
|
| Service life |
- Mechanically: 5,000,000 operations min
- Electrically: 500,000 operations min.
|